Pilot Unloader Check Valve – Replaces Atlas Copco 1312100497 – 145–175 PSI

Pilot Unloader Check Valve – Replaces Atlas Copco 1312100497 – 145–175 PSI

Regular price $134.95 USD
Regular price Sale price $134.95 USD
Sale Sold out
Orders $25 or more ship free to the lower 48. Shipping details.
Condition : New

View full details

Product Description

Pilot unloader check valve replacing Atlas Copco 1312100497 for matching gas-driven air compressors. The combination assembly controls loading and unloading, retains receiver pressure and includes a cold-start unloader, manual hand unloader and muffled exhaust.

OEM replacement reference: Replaces Atlas Copco / BelAire / Chicago Pneumatic 1312100497. Supplied Conrader configuration: NG20-M-SU4-14-SST, factory pressure cycle 145–175 PSI. Match the complete configuration to your compressor.

Connections and specifications

Specification Detail
Discharge inlet 3/4″ compression tube, side entry; 1-18 UNS-2A fitting thread
Tank outlet 1/2″ MNPT; 1/2-14 NPT
Pilot / throttle signal port 1/8″ FNPT; match the existing signal-line fitting
Cold-start control SU4 automatic start unloader with brass seal
Manual control Hand unloader
Exhaust Muffler included (M option)
Thread treatment SST thread-sealant option
Rated flow 30 SCFM at 100 PSIG (NG technical sheet)
Body / fittings Brass
Operating temperature −15°F to 400°F (current NG specification)

Factory pressure cycle

Function Pressure
Load / pumping resumes 145 PSI
Unload / discharge vents 175 PSI
Differential 30 PSI

Documented compressor and idle-control references

The OEM manuals below identify 1312100497 as the unloader valve on these gas-drive configurations. They identify separate idle controls by model; those controls are not included with this valve. Match the machine’s model, serial revision, connections and pressure cycle before ordering.

Compressor model in OEM manual Separate idle-control OEM reference
BelAire 59G3HR, 3G3HH, 3G3HHL 1312100382
BelAire 59G3HB 1312100742
BelAire 3G3HK, 3G3HKL 1312100099
BelAire 6G3HV 1312100741
Chicago Pneumatic RCP-930G, RCP-1130G, RCP-1330G 1312100382
Chicago Pneumatic RCP-1030G 1312100742
Chicago Pneumatic RCP-1430GK, RCP-1430G 1312100099
Chicago Pneumatic RCP-C1630G 1312100741

How it works

During loaded operation, air passes through the check valve into the receiver. At 175 PSI, the pilot opens the unloading path so the compressor can run unloaded while the check valve retains tank pressure. Pumping resumes at 145 PSI. The SU4 start unloader relieves discharge pressure during startup; the manual hand unloader provides manual unloading.

Confirm the side-entry compression connection, tank thread, startup control and throttle arrangement. This is an OEM replacement assembly manufactured by Conrader. A matching pilot port alone does not establish that a particular throttle cable fits the engine.