Pilot Unloader Check Valve – Replaces Atlas Copco 1312100497 – 145–175 PSI
Pilot Unloader Check Valve – Replaces Atlas Copco 1312100497 – 145–175 PSI
Couldn't load pickup availability
View full details
Product Description
Pilot unloader check valve replacing Atlas Copco 1312100497 for matching gas-driven air compressors. The combination assembly controls loading and unloading, retains receiver pressure and includes a cold-start unloader, manual hand unloader and muffled exhaust.
OEM replacement reference: Replaces Atlas Copco / BelAire / Chicago Pneumatic 1312100497. Supplied Conrader configuration: NG20-M-SU4-14-SST, factory pressure cycle 145–175 PSI. Match the complete configuration to your compressor.
Connections and specifications
| Specification | Detail |
|---|---|
| Discharge inlet | 3/4″ compression tube, side entry; 1-18 UNS-2A fitting thread |
| Tank outlet | 1/2″ MNPT; 1/2-14 NPT |
| Pilot / throttle signal port | 1/8″ FNPT; match the existing signal-line fitting |
| Cold-start control | SU4 automatic start unloader with brass seal |
| Manual control | Hand unloader |
| Exhaust | Muffler included (M option) |
| Thread treatment | SST thread-sealant option |
| Rated flow | 30 SCFM at 100 PSIG (NG technical sheet) |
| Body / fittings | Brass |
| Operating temperature | −15°F to 400°F (current NG specification) |
Factory pressure cycle
| Function | Pressure |
|---|---|
| Load / pumping resumes | 145 PSI |
| Unload / discharge vents | 175 PSI |
| Differential | 30 PSI |
Documented compressor and idle-control references
The OEM manuals below identify 1312100497 as the unloader valve on these gas-drive configurations. They identify separate idle controls by model; those controls are not included with this valve. Match the machine’s model, serial revision, connections and pressure cycle before ordering.
| Compressor model in OEM manual | Separate idle-control OEM reference |
|---|---|
| BelAire 59G3HR, 3G3HH, 3G3HHL | 1312100382 |
| BelAire 59G3HB | 1312100742 |
| BelAire 3G3HK, 3G3HKL | 1312100099 |
| BelAire 6G3HV | 1312100741 |
| Chicago Pneumatic RCP-930G, RCP-1130G, RCP-1330G | 1312100382 |
| Chicago Pneumatic RCP-1030G | 1312100742 |
| Chicago Pneumatic RCP-1430GK, RCP-1430G | 1312100099 |
| Chicago Pneumatic RCP-C1630G | 1312100741 |
How it works
During loaded operation, air passes through the check valve into the receiver. At 175 PSI, the pilot opens the unloading path so the compressor can run unloaded while the check valve retains tank pressure. Pumping resumes at 145 PSI. The SU4 start unloader relieves discharge pressure during startup; the manual hand unloader provides manual unloading.
Confirm the side-entry compression connection, tank thread, startup control and throttle arrangement. This is an OEM replacement assembly manufactured by Conrader. A matching pilot port alone does not establish that a particular throttle cable fits the engine.
Manufacturer documentation: NG technical sheet and option codes · NG series specifications · BelAire manual, gas-drive parts (page 21) · Chicago Pneumatic manual, gas-drive parts (page 21).